Papua New Guinea SG6.0/8.0/10RS-CN

Compatible with high-power photovoltaic modules and double-sided modules
Lower start-up voltage and wider MPPT voltage range
Built-in intelligent PID repair function

Category:

Papua New GuineaSolar Inverter

Product Description

Technical parameters

Input (DC)

  SG6.0RS-CN SG8.0RS-CN SG10S-CN
Maximum input voltage: 600 V 600 V 600 V
Minimum input voltage/starting voltage: 40V/50V 40V/50V 40V/50V
Rated input voltage: 360 V 360 V 360 V
MPPT voltage range: 40V-560V 40V-560V 40V-560V
Maximum number of MPPT strings per channel: 16 A 2/1 16 A
Maximum input current per channel: 32A( 16 A/ 16 A) 16 A 48 A ( 16 A/16 A/16 A)
Maximum input current: 2 48A(16 A/32A) 20 A
MPPT Quantity: 20 A 2 60A(20A/20 A/20A)
Maximum allowable current of input terminal: 40A(20A/20 A) 20 A 600 V
Maximum DC short circuit current: 600 V 60A(40 A/20A) 40V/50V
Maximum input voltage: 40V/50V 600 V 360 V
Minimum input voltage/starting voltage: 360 V 40V/50V 40V-560V

Output (AC)

  SG6.0RS-CN SG8.0RS-CN SG10RS-CN
Rated output power: 6000 W 8000 W 10000 W
Maximum output power: 6600 W 8800 W 11000 W
Maximum output apparent power: 6600 and pad 8800 and pad 11000 and pad
Maximum output current: 30.0 A 40.0 A 50.0 A
Rated grid voltage: 1 / N / PE, 230 V , 220 V 1 / N / PE, 230 V , 220 V 1 / N / PE, 230 V , 220 V
Grid voltage range: 154 V - 276 V 154 V - 276 V 154 V - 276 V
Rated grid frequency/grid frequency range: 50 Hz / 45 Hz -55Hz;60Hz/55 Hz -65Hz 50 Hz / 45 Hz -55Hz;60Hz/55 Hz -65Hz 50 Hz / 45 Hz -55Hz;60Hz/55 Hz -65Hz
total current waveform distortion rate: <3% (at rated power) <3% (at rated power) <3% (at rated power)
DC component: < 0.5 % In < 0.5 % In < 0.5 % In
Power factor: > 0.99 (at rated power) > 0.99 (at rated power) > 0.99 (at rated power)
power factor adjustable range: 0.8 lead -0.8 lag 0.8 lead -0.8 lag 0.8 lead -0.8 lag
Number of feed phases/number of output phases: 1 / 1 1 / 1 1 / 1

Efficiency

  SG6.0RS-CN SG8.0RS-CN SG10RS-CN
Maximum efficiency: 97.90 % 97.80 % 97.80 %
Efficiency in Europe: 97.50 % 97.30 % 97.40 %

Protection and Function

  SG6.0RS-CN SG8.0RS-CN SG10RS-CN
DC reverse connection protection: Have Have Have
AC Short Circuit Protection: Have Have Have
Leakage current protection: Have Have Have
Grid monitoring: Have Have Have
DC Switch: Have Have Have
Group string detection: Have Have Have
PID-Zero : Have Have Have
Island Protection: Have Have Have
Surge protection: Have Have Have
DC reverse connection protection: Have Have Have
AC Short Circuit Protection: Have Have Have
Leakage current protection: DC secondary/AC secondary DC secondary/AC secondary DC secondary/AC secondary

General Parameters

  SG6.0RS-CN SG8.0RS-CN SG10RS-CN
Dimensions (width * height * depth): 445*325*150 mm 525*365 *170 mm 525*365*170 mm
Weight: 10.5 kg 18 kg 18 kg
Isolation mode: No transformer No transformer No transformer
Protection class: IP65 IP65 IP65
Night loss: <3 W <3 W <3 W
Operating temperature range: -25 ℃-60 ℃ -25℃C-60℃C -25℃C-60℃C
Operating humidity range (without condensation): 0%-100 % 0%-100% 0%-100%
Cooling method: Natural heat dissipation Natural heat dissipation Natural heat dissipation
Maximum working altitude: 4000 m 4000 m 4000 m
Noise: <35 dB <35 dB <35 dB
Display: LED LED LED
Communications: 4G 4G 4G
DC terminal type: MC4 compatible terminal (up to 6 mm2) MC4 compatible terminal (up to 6 mm2) MC4 compatible terminals (max. 6 mm2)
AC terminal type: 0T compatible terminal (max. 16 mm2) OT compatible terminals (max. 16 mm2) OT compatible terminals (max. 16 mm2)
Conform to the standard: NB/T 32004-2018,GB/T37408-2019 NB/T 32004-2018,GB/T37408-2019 NB/T 32004-2018,GB/T37408-2019
Grid Support: Active and reactive power regulation and power change slope control Active and reactive power regulation and power change slope control Active and reactive power regulation and power change slope control