south sudan republic SG36/40/50CX-P2H-CN
Adaptive weak grid, grid-friendly and high yield.
20A DC side input, can be adapted to 210 large components
Wide working voltage range, early start, late shutdown, more lasting power generation
20A DC side input, can be adapted to 210 large components
Wide working voltage range, early start, late shutdown, more lasting power generation
Category:
south sudan republicSolar Inverter
Product Description
Technical parameters
Input (DC)
| SG36CX-P2H-CN | SG40CX-P2H-CN | SG50CX-P2H-CN | |
| Maximum input voltage: | 1100 V | 1100 V | 1100 V |
| Minimum input voltage/starting voltage: | 160 V/200 V | 160 V/200 V | 160 V/200 V |
| Rated input voltage: | 600 V | 600 V | 600 V |
| MPPT voltage range: | 160V-1000V | 160V-1000V | 160V-1000V |
| Maximum number of MPPT input strings per channel: | 2/1/1 | 2/1/1 | 2/1/1 |
| Maximum input current per channel: | 20 A | 20 A | 20 A |
| Maximum input current: | 80A(40A/20A/20A) | 80A(40A/20A/20A) | 80A(40A/20A/20A/20A) |
| MPPT Quantity: | 3 | 3 | 3 |
| Maximum allowable current of input terminal: | 30 A | 30 A | 30 A |
| Maximum DC short circuit current: | 100A(50A/25A/25A) | 100A(50A/25A/25A) | 100A(50A/25A/25A) |
Output (AC)
| SG36CX-P2H-CN | SG40CX-P2H-CN | SG50CX-P2H-CN | |
| Rated output power: | 36 kW | 40 kW | 50 kW |
| Maximum output power: | 39.6 kW | 44 kW | 55 kW |
| Maximum output apparent power: | 39.6 kVA | 44 kVA | 55 kVA |
| Maximum output current: | 60.2 A | 66.9 A | 83.6 A |
| Rated grid voltage: | 3/N/PE,230V/400V,220V/380 V | 3/N/PE,230V/400V,220V/380 V | 3/N/PE,230V/400V, 220 V/380 V |
| Grid voltage range: | 312 V-480 V | 312V-480V | 312 V-480 V |
| Rated grid frequency/grid frequency range: | 50Hz/45Hz- 55 Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz |
| total current waveform distortion rate: | <3% (at rated power) | <3% (at rated power) | <3% (at rated power) |
| DC component: | <0.5 % ln | <0.5 % ln | <0.5 % In |
| Power factor: | > 0.99 (at rated power) | > 0.99 (at rated power) | > 0.99 (at rated power) |
| power factor adjustable range: | 0.8 lead -0.8 lag | 0.8 lead -0.8 lag | 0.8 lead -0.8 lag |
| Feed phase number/output phase number: | 3/3-N-PE | 3/3-N-PE | 3/3-N-PE |
Efficiency
| SG36CX-P2H-CN | SG40CX-P2H-CN | SG50CX-P2H-CN | |
| Maximum efficiency: | 98.6% | 98.6% | 98.6% |
| Efficiency in China: | 98% | 98% | 98% |
Protection and Function
| SG36CX-P2H-CN | SG40CX-P2H-CN | SG50CX-P2H-CN | |
| DC reverse connection protection: | Have | Have | Have |
| AC Short Circuit Protection: | Have | Have | Have |
| Leakage current protection: | Have | Have | Have |
| Grid monitoring: | Have | Have | Have |
| DC Switch: | Have | Have | Have |
| Group string detection: | Have | Have | Have |
| Island Protection: | Have | Have | Have |
| Surge protection: | DC secondary/AC secondary | DC secondary/AC secondary | DC secondary/AC secondary |
General Parameters
| SG36CX-P2H-CN | SG40CX-P2H-CN | SG50CX-P2H-CN | |
| Dimensions (width * height * depth): | 605 mm*575 mm*245 mm | 605 mm*575 mm*245 mm | 605 mm*575 mm*245 mm |
| Weight: | 35 kg | 35 kg | 35 kg |
| Isolation mode: | No transformer | No transformer | No transformer |
| Protection class: | IP66 | IP66 | IP66 |
| Night loss: | ≤ 1W | ≤ 1W | ≤ 1W |
| Operating temperature range: | -30 ℃ C- 60C | -30 ℃ C- 60C | -30 ℃ C- 60C |
| Operating humidity range (without condensation): | 0%-100 % | 0%-100 % | 0%-100 % |
| Cooling method: | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling |
| Maximum working altitude: | 4000 m(>2000m derating) | 4000 m(>2000m derating) | 4000 m(>2000m derating) |
| Noise: | ≤ 66 dB | ≤ 66 dB | ≤ 66 dB |
| Display: | LED, Bluetooth APP | LED, Bluetooth APP | LED, Bluetooth APP |
| Communications: | 4G | 4G | 4G |
| DC terminal type: | Evo2 compatible terminal | Evo2 compatible terminal | Evo2 compatible terminal |
| AC terminal type: | OT/DT terminals (max. 35 mm2) | OT/DT terminals (max. 35 mm2) | OT/DT terminals (max. 35 mm2) |
| Conform to the standard: | NB/T32004-2018,GB/T37408-2019 | NB/T32004-2018,GB/T37408-2019 | NB/T32004-2018,GB/T37408-2019 |
| Grid Support: | Anti-islanding, active and reactive power regulation, PF control, slow start/shutdown | Anti-islanding, active and reactive power regulation, PF control, slow start/shutdown | Anti-islanding, active and reactive power regulation, PF control, slow start/shutdown |